POOL 1 - POOL 2 (ACCESSORY IS REQUIRED)
pool4.1.1
activated
start temp
stop temperature
°C
°C
start temp
Setting range: 5.0 - 80.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 5.0 - 80.0 °C
Default value: 24.0 °C
maximum number of
compr.
Setting range: 1 8
Factory setting: 8
Menu
4.1.1 -
4.1.2
Select whether the pool control is to be activated, within what temperatures
(start and stop temperature) pool heating must occur and how many compressors
may work against the pool at the same time.
Maximum number gives the possibility of restricting the number of compressors
that are permitted to work with pool heating. The setting can be adjusted if re-
quirements other than pool heating must be prioritised for example.
When the pool temperature drops below the set start temperature and there is
no hot water or heating requirement, SMO 40 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value that is higher than the
stop temperature.