DEGREE MINUTE SETTING
current value
start compressor
start diff additional heat
diff. between additional steps
DM
DM
DM
DM
degree minute setting4.9.3
step difference compressors
DM
current value
Setting range: -3000 – 3000
start compressor
Setting range: -1000 – -30
Default value: -60
step difference
compressors
Setting range: 10 – 2000
Default value: 60
start diff additional heat
Setting range: 100 – 2000
Factory setting: 400
diff. between additional steps
Setting range: 10 – 1000
Factory setting: 30
Menu
4.9.3
Degree minutes are a measurement of the current heating requirement in the
house and determine when the compressor respectively additional heat will
start/stop.
Caution
Higher value on "start compressor" gives more compressor starts,
which increase wear on the compressor. Too low value can give uneven
indoor temperatures.
NIBE SMO 40Chapter 3 | SMO 40 – at your service74