time betw. switch heat/cool (Displayed if cooling in 2-pipe
system is activated.)
Setting range: 0 48 h
Factory setting: 2
op mode auto EQ1-GP12
Here you set whether you want the cooling pump (GP12) to run in operating
mode auto.
cooling pump speed
Setting range: 1 100%
Factory setting: 70%
You can use VVM 320 to cool the house during hot periods of the year.
Caution
Certain setting options only appear if their function is installed and
activated in VVM 320.
delta at +20 °C
Set the desired temperature on the temperature difference between supply and
return lines to the climate system during cooling operation when the outdoor
temperature is +20 °C. VVM 320 then attempts to get as close to the set tem-
perature as possible.
delta at +40 °C
Set the desired temperature on the temperature difference between supply and
return lines to the climate system during cooling operation when the outdoor
temperature is +40 °C. VVM 320 then attempts to get as close to the set tem-
perature as possible.
use room sensor
Here you can set whether room temperature sensors are to be used in cooling
mode.
NIBE VVM 320Chapter 3 | VVM 320 at your service40

Table of Contents

Other manuals for Nibe VVM 320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe VVM 320 and is the answer not in the manual?

Nibe VVM 320 Specifications

General IconGeneral
Dimensions (HxWxD)1800 x 600 x 615 mm
Power Supply230 V
Frequency50 Hz
Protection classIP21
Compatible withNibe heat pumps
DisplayTouch display
Smart Home IntegrationYes, via NIBE Uplink
Operating temperature0°C to +45°C
Relative humidityMax. 95 %
TypeControl unit for heat pumps

Related product manuals