EasyManua.ls Logo

Nibe VVM 320 - Advanced Cooling Operation Settings; Using Room Sensors for Cooling

Nibe VVM 320
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
time betw. switch heat/cool (Displayed if cooling in 2-pipe
system is activated.)
Setting range: 0 48 h
Factory setting: 2
op mode auto EQ1-GP12
Here you set whether you want the cooling pump (GP12) to run in operating
mode auto.
cooling pump speed
Setting range: 1 100%
Factory setting: 70%
You can use VVM 320 to cool the house during hot periods of the year.
Caution
Certain setting options only appear if their function is installed and
activated in VVM 320.
delta at +20 °C
Set the desired temperature on the temperature difference between supply and
return lines to the climate system during cooling operation when the outdoor
temperature is +20 °C. VVM 320 then attempts to get as close to the set tem-
perature as possible.
delta at +40 °C
Set the desired temperature on the temperature difference between supply and
return lines to the climate system during cooling operation when the outdoor
temperature is +40 °C. VVM 320 then attempts to get as close to the set tem-
perature as possible.
use room sensor
Here you can set whether room temperature sensors are to be used in cooling
mode.
NIBE VVM 320Chapter 3 | VVM 320 at your service40

Table of Contents

Other manuals for Nibe VVM 320

Related product manuals