COOLING SETTINGS (ACCESSORY REQUIRED)
cooling1.9.5
set pt value cool/heat sensor
heat at room under temp.
cool at room over temp.
use room sensor
°C
°C
°C
delta at +20 °C
Setting range: 3 - 10 °C
Default value: 3
delta at +40 °C
Setting range: 3 - 10 °C
Default value: 6
Menu
1.9.5
heat/cool sen.
Factory setting: no sensor selected
set pt value cool/heat sensor
Setting range: 5 - 40 °C
Default value: 21
heat at room under temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
cool at room over temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
start active cooling
Setting range: 10 300
Default value: 0
degree minutes cooling
Setting range: -3000 - 3000 cooling degree minutes
Factory setting: 0
39Chapter 3 | VVM 320 at your serviceNIBE VVM 320

Table of Contents

Other manuals for Nibe VVM 320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe VVM 320 and is the answer not in the manual?

Nibe VVM 320 Specifications

General IconGeneral
Dimensions (HxWxD)1800 x 600 x 615 mm
Power Supply230 V
Frequency50 Hz
Protection classIP21
Compatible withNibe heat pumps
DisplayTouch display
Smart Home IntegrationYes, via NIBE Uplink
Operating temperature0°C to +45°C
Relative humidityMax. 95 %
TypeControl unit for heat pumps

Related product manuals