POOL (ACCESSORY IS REQUIRED)
pool4.1.1
activated
start temp
stop temperature
°C
°C
start temp
Setting range: 5.0 - 80.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 5.0 - 80.0 °C
Default value: 24.0 °C
Menu
4.1.1
Select whether the pool control is to be activated and within what temperatures
(start and stop temperature) pool heating must occur.
When the pool temperature drops below the set start temperature and there is
no hot water or heating requirement, VVM 320 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value that is higher than the
stop temperature.
INTERNET
nibe uplink
internet4.1.3
tcp/ip settings
proxy settings
Here you make settings for connecting
VVM 320 to the internet.
NOTE
For these functions to work the
network cable must be connec-
ted.
Menu
4.1.3