NE200/300 Series Drive User Manual
Chapter 6 Parameter description 183
upper limit【0.00Hz】
FF.02 Reference frequency at latest
fault
Setting range: 0~Frequency
upper limit【0.00Hz】
FF.03 Output current at latest fault
Setting range: 0~2* drive rated
current【0.0A】
FF.04 Bus voltage frequency at
latest fault
Setting range: 0~1000V【0V】
FF.05 Running status at latest fault Setting range: 0~3【0】
FF.06 Fault history 1 (Last One) Setting range: Same with FF.00
FF.07 Fault history 2 Setting range: Same with FF.00
Memorize the types of the latest 3 faults (See “chapter 7: fault/ alarm
information table” for the details of faults). And record the output frequency,
reference frequency, output current, DC bus voltage and running status of
the latest fault for troubleshooting.
FF.08 Total power on time Range: 0~65530h【0】
FF.09 Total running time Range: 0~65530h【0】
The total boot time and runtime accumulated automatically by Drive.
FF.10 Reserved Reserved
FF.11 Software version number of
control board
Range: 1.00~10.00【1.00】
FF.12 Non-standard version
number of software
Range: 0~255【0】
These two parameters indicate the software version of the product and
also the non-standard version, which helps to identify the product.
FF.13
Heat sink temperature Range: -30.0~120.0°C
FF.13
IGBT temperature Range: 0.0~140.0°C