NE200/300 Series Drive User Manual
Chapter 6 Parameter description 183
upper limit0.00Hz
FF.02 Reference frequency at latest
fault
Setting range: 0Frequency
upper limit0.00Hz
FF.03 Output current at latest fault
Setting range: 02* drive rated
current0.0A
FF.04 Bus voltage frequency at
latest fault
Setting range: 01000V0V
FF.05 Running status at latest fault Setting range: 030
FF.06 Fault history 1 (Last One) Setting range: Same with FF.00
FF.07 Fault history 2 Setting range: Same with FF.00
Memorize the types of the latest 3 faults (See “chapter 7: fault/ alarm
information table” for the details of faults). And record the output frequency,
reference frequency, output current, DC bus voltage and running status of
the latest fault for troubleshooting.
FF.08 Total power on time Range: 065530h0
FF.09 Total running time Range: 065530h0
The total boot time and runtime accumulated automatically by Drive.
FF.10 Reserved Reserved
FF.11 Software version number of
control board
Range: 1.0010.001.00
FF.12 Non-standard version
number of software
Range: 02550
These two parameters indicate the software version of the product and
also the non-standard version, which helps to identify the product.
FF.13
Heat sink temperature Range: -30.0120.0°C
FF.13
IGBT temperature Range: 0.0140.0°C