NE200/300 Series Drive User Manual
54 Chapter 4 Operation and Display
without saving the parameter, and stay at current function code.
Below is the example of modifying the function code F9.01 from
10.00Hz to 20.00Hz. (The number of bigger font size refers to the blinking
digit),
Fig.4-2 Example of 3 levels menu operating
At level-3 menu, if the parameter has no blinking digit, it indicates that
this function code cannot be modified. The possible reasons include:
1) The function code is an unchangeable parameter, such as actual
detection parameter, running record parameter, etc.
2) The function code cannot be modified in running status. It can be
modified only after the drive running is stopped.
4.3 Display status of keypad
Displaying status include the stopped state parameter display, the
running status parameter display, the function code edition display and the
fault warning condition display etc.
1) The stop status parameter display
The drive is at stop state. The LED displays the stop state parameters.
You can press ā€œ>>ā€ to by turns display different parameters at stop state.
(User can set which parameters are to be displayed at stop state in FE
group function codes.)