EasyManua.ls Logo

Nidec NE200 - 6.8 Output terminals group (F7)

Nidec NE200
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200/300 Series Drive User Manual
68 Chapter 5 List of Parameters
Code
Description
Setting range Default
Modify
Modbus
Address
F4.00
V/F curve
setting
0: Constant torque load
V/F
0 × 0500H
1: 2.0 power decreasing
torque
2: 1.5 power decreasing
torque
3: 1.2 power decreasing
torque
4: Multiple dots V/F
F4.01
V/F freq. F1 0.0
F4.03 10.00Hz
× 0501H
F4.02
V/F voltage
V1
0.0
100.0% 20.00%
× 0502H
F4.03
V/F freq. F2 F4.01
F4.05 25.00Hz
× 0503H
F4.04
V/F voltage
V2
0.0
100.0% 50.00%
× 0504H
F4.05
V/F freq. F3 F4.03
F0.10 40.00Hz
× 0505H
F4.06
V/F voltage
V3
0
100.0% 80.00%
× 0506H
F4.07
Torque boost
0.0%: Auto boost
0.00%
0507H
0.1
30.0%: Manual
boost
F4.08
Manual
torque boost
cutoff point
0.00
60.00Hz 50.00Hz
0508H
F4.09
Slip
compensation
coefficient
0.0
200.0% 0.00% 0509H
F4.10
Slip
compensation
filtering time
0.01
2.55s 0.20s 050AH

Table of Contents

Related product manuals