EasyManua.ls Logo

Nidec NE200 - Page 79

Nidec NE200
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NE200/300 Series Drive User Manual
70 Chapter 5 List of Parameters
Code
Description
Setting range Default
Modify
Modbus
Address
F5.03
rated current
②
0.01
~
655.35A
③
0.1~999.9A
Depends
on
model
○ 0603H
F5.04
rated speed
②
0
~
65535RPM
③
0
~
24000 RPM
Depends
on
model
○ 0604H
F5.05
No-load
current I0
②
0.01
~
655.35A
③
0.1
~
999.9A
Depends
on
model
○ 0605H
F5.06
②
Stator
resistance
R1
1
~
65535mΩ
Depends
on
model
○ 0606H
③
Stator
resistance
R1
1
~
65535mΩ(Drive rated
power≤22kW)
0.1
~
6553.5mΩ(Drive
rated power>22kW)
Depends
on
model
○
0606H
F5.07
②
Leakage
inductive
reactance X
0.01
~
655.35mH
Depends
on
model
○ 0607H
③
Leakage
inductive
reactance X
0.01
~
655.35mH(Drive
rated power≤22kW)
0.001
~
65.535mH(Drive
rated power>22kW)
Depends
on
model
○ 0607H
F5.08
②
Rotor
resistance
R2
1
~
65535mΩ
Depends
on
model
○ 0608H
③
Rotor
resistance
R2
1
~
65535mΩ(Drive rated
power≤22kW)
0.1
~
6553.5mΩ(Drive
rated power>22kW)
Depends
on
model
○ 0608H
F5.09
②
Mutual
Inductive
reactance
Xm
0.1
~
6553.5mH
Depends
on
model
○ 0609H

Table of Contents