Chapter 5 List of Parameters 81
Code
Description Setting range Default
Modify
Modbus
Address
F7.23
Reserve
Reserve Reserve
Reserve
0817H
AO2 output
range selection
0: 0
10V/0
20mA
1: 2
10V/4
20mA
0 0817H
F7.24
Gain of AO
1
200% 100%
0818H
Gain of AO1
0818H
F7.25
Reserve
Reserve Reserve
Reserve
0819H
Gain of AO2
1~200% 100% 0819H
F7.26
Y1 Max.
output pulse
freq.
Y1 Min. output pulse
freq.
50.00kHz
10.00kHz
081AH
DO Max.
output pulse
freq.
DO
最小输出脉冲频
率~
50.00kHz
081AH
F7.27
Y1 Min.
output pulse
freq.
0.00
Y1 Max.
output pulse freq.
0.00kHz
081BH
DO Min.
output pulse
freq.
0.00
DO Max.
output pulse freq.
0.00kHz
081BH
F7.28
Auxiliary pump
start lag time
0
9999s 0 081CH
F7.29
Auxiliary pump
stop lag time
0
9999s 0 081DH
F7.30
Y1 Max.
output
0: 50.00KHz
1: 500.0Hz
0 ×
081EH
DO Max.
output
081EH
F7.31
FDT/RUN signal
Jog selection
0: Include Jog signal
0 × 081FH
1: Do not include
Jog signal
F7.32
Running time
arrival setup
0~65530Mins 0 0820H
F7.33
Running time
arrival stop
0: Do not stop
0
0821H
1: Stop