EasyManua.ls Logo

Nikon D7000 - Inspection and Adjustment of Flange-Back (Body-Back)

Nikon D7000
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
󲩎󲨺󲨹󲨪󲨱󲨨󲨨󲨩󲨥󲩊󲨦󲨫󲨰󲨩󲨬󲨦󲨹
󲨥󲨘󲨹󲨬󲨬 󳉗 󲨼󲨯󲨨󲨨󲨨󲨘󲨥
Inspection and adjustment of ange-back (body-back)
Refer to "
Models WITH rear body" of "Inspection and adjustment of ange-back (body-back)" of
D/SLR ADJUSTMENT Separate Volume
for details.
Rotational direction/divisions of scale: Turn the index circle by 17 divisions of scale in the
direction of the arrow so that the needle is on "0.17 mm" position.
<Standard> (Body-back) distance: 48.5mm
-0.025mm
+0.005mm
/parallelism: 0.015mm or less
Caution: For some bodies, the washers are already put (1) on the face of the camera-body for mounting the image
sensor unit, and (2) on the attaching face of the image-sensor unit. In this case, there are marks at the
following two types of marking position.
(1)The face of camera body for mounting the image sensor unit: To adjust the height of the camera body
󲴯
In case of disassembling/replacing the image sensor unit, put the washers back to the original positions.
Tool (device)
J19004-1 J18001-1
Dial indicator and stand Body-back focus gauge
Color of
mark
Sub-
No.
Part No.
Thickness of
washer (mm)
Blue 63A 6K050-084 T = 0.02
Red 63B 6K050-085-1 T = 0.1
Green 63C 6K050-086 T = 0.06
Color of
mark
Sub-
No.
Part No.
Thickness of
washer (mm)
Blue 63A 6K050-084 T=0.02
Red 63B 6K050-085-1 T=0.1
Green 63C 6K050-086 T=0.06
Marking position
Marking position
(2)The attaching face of image sensor unit: To adjust the height of the image sensor unit
󲴯
Remove the wahsers when the image sensor unit must be replaced.