Inspection and adjustment of ange-back (body-back)
Refer to "
②
Models WITH rear body" of "Inspection and adjustment of ange-back (body-back)" of
D/SLR ADJUSTMENT Separate Volume
①
for details.
Rotational direction/divisions of scale: Turn the index circle by 17 divisions of scale in the
direction of the arrow so that the needle is on "0.17 mm" position.
<Standard> (Body-back) distance: 48.5mm
-0.025mm
+0.005mm
/parallelism: 0.015mm or less
Caution: For some bodies, the washers are already put (1) on the face of the camera-body for mounting the image
sensor unit, and (2) on the attaching face of the image-sensor unit. In this case, there are marks at the
following two types of marking position.
(1)The face of camera body for mounting the image sensor unit: To adjust the height of the camera body
In case of disassembling/replacing the image sensor unit, put the washers back to the original positions.
•
Tool (device)
J19004-1 J18001-1
Dial indicator and stand Body-back focus gauge
Color of
mark
Sub-
No.
Part No.
Thickness of
washer (mm)
Blue 63A 6K050-084 T = 0.02
Red 63B 6K050-085-1 T = 0.1
Green 63C 6K050-086 T = 0.06
Color of
mark
Sub-
No.
Part No.
Thickness of
washer (mm)
Blue 63A 6K050-084 T=0.02
Red 63B 6K050-085-1 T=0.1
Green 63C 6K050-086 T=0.06
Marking position
Marking position
(2)The attaching face of image sensor unit: To adjust the height of the image sensor unit
Remove the wahsers when the image sensor unit must be replaced.