42Service Manual – SC5000 04 - Control System
1-002 K1 KSI Rly Coil Short
Description The controller has detected a short circuit to the KSI relay coil.
Setting
Conditions
The amp draw exceeds 5 amps
When Monitored
Always
Possible Causes Short in the relay coil. Short to battery in the control line.
Initial Action None
Troubleshooting Steps
1. Disconnect the spade lugs from the relay terminals, and check if the error persists.
− If the error clears, replace the relay.