37Service Manual – SC5000 04 - Control System
Inactivity Time (min): This sets the length of time (in minutes) before the machine powers down after
inactivity. The minimum is 1 minute, the maximum is 30 minutes, and the increment is every minute.
Impact Detect: This sets how the machine handles impact detection. The choices are Off, record to log, and
lockout the machine.
Impact Level: This sets the threshold for impact detection. The choices are high and low.
Conguration Menu
The conguration menu provides technician-only access to congure the machine based on which options
are installed. If you install an option to a customer’s machine, you will need to congure the controller to
specify that the option is installed, or the option may not function. Additional information is contained in the
instruction sheets that accompany the option kits.
Brand: This sets the branding of the machine (Nilsk or Advance). This should never be changed unless you
are replacing the main controller.
Deck: This sets the deck type installed on the machine. The options are (Advance/Nilsk) 34D/860D,
32C/810C, and 36C/910C.
Side Sweep: This sets whether the optional side broom is installed. This option is available only for
36C/910C machines. If the side broom kit also includes Dust Guard, you will also need to set the option
pump type too.
Ecoex:This sets whether the EcoFlex detergent pump system is installed.
Opt Pump: This sets whether the spray wash option pump is installed.
Battery: This sets the battery type for the purpose of battery voltage monitoring. The choices are Wet and
AGM. The battery types will have slightly different voltage levels during their discharge cycles.
Charger: This sets whether the onboard battery charger is installed.
Vacuum: This sets whether there is 1 vacuum motor or 2 vacuum motors.
Beacon: This sets whether the beacon is installed.
TrackClean-1: This sets whether the TrackClean-1 module is installed.