EasyManua.ls Logo

Nilfisk-Advance Advance SC5000

Nilfisk-Advance Advance SC5000
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
110Service Manual – SC5000 24 - Electrical System
Battery Charger Error Codes
8-E001 High battery voltage
Description Battery voltage too high.
Setting
Conditions
The battery voltage is higher than the software setting.
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
Check the battery voltage and cable connections.
Check battery size and condition.
This error will automatically clear once the condition has been corrected.
8-E002 Low battery voltage
Description Battery voltage too low to start a charge cycle.
Setting
Conditions
Algorithm dependent – typically 0.1V/cell.
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
Check the battery voltage and cable connections.
Check battery size and condition. Batteries may be overdischarged.
Use another charger to bring the batteries above the minimum voltage.
This error will automatically clear once the condition has been corrected.