45Service Manual – SC5000 04 - Control System
1-101 Solution Solenoid Short
Description Solution solenoid - too much current
Setting
Conditions
Amp Draw is higher than 5 Amps
When Monitored
Always
Possible Causes
Shorted Solution Solenoid
Control wire shorted to power
Initial Action None
Troubleshooting Steps
Disconnect the solution solenoid and check if the error persists.
If the error persists, the control wire is shorted to battery positive power. Repair or replace the
harness.
If the error clears, replace the solenoid.
1-102 Beacon Short
Description Beacon - too much current
Setting
Conditions
Amp Draw is higher than 5 Amps
When Monitored
Always
Possible Causes
Shorted beacon
Control wire shorted to power
Initial Action None
Troubleshooting Steps
Disconnect the beacon and check if the error persists.
If the error persists, the control wire is shorted to battery positive power. Repair or replace the
harness.
If the error clears, replace the beacon.
1-103 Backup Alarm Short
Description Backup Alarm - too much current
Setting
Conditions
Amp Draw is higher than 5 Amps
When Monitored
Always
Possible Causes
Shorted backup alarm
Control wire shorted to power
Initial Action None
Troubleshooting Steps
Disconnect the backup alarm and check if the error persists.
If the error persists, the control wire is shorted to battery positive power. Repair or replace the
harness.
If the error clears, replace the alarm.