47Service Manual – SC5000 04 - Control System
1-201 Level Sensor
Description Solution tank level sensor voltage is out of range.
Setting
Conditions
When Monitored
Always
Possible Causes
Broken sensor
Control wire shorted to power
Initial Action None
Troubleshooting Steps
Disconnect the solution sensor and check if the error persists.
If the error persists, the control wire is shorted to battery positive power. Repair or replace the
harness.
If the error clears, replace the sensor.
1-560 EEPROM Cong Fault
1-561 EEPROM Options
1-562 EEPROM Sys Values
1-563 EEPROM Fault Log
1-564 EEPROM User Key List
1-565 EEPROM Impact Log
1-566 EEPROM Statistics
Description Unable to read EEPROM values - using default values
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action
Hard power cycle the machine by disconnecting the main bat. If the error persists,
replace the main controller.
Troubleshooting Steps

Table of Contents

Other manuals for Nilfisk-Advance Advance SC5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advance SC5000 and is the answer not in the manual?

Nilfisk-Advance Advance SC5000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvance SC5000
CategoryScrubber
LanguageEnglish

Related product manuals