90Service Manual – SC5000 20 - Drive System
3-081 Low FET Error
3-082 High FET Error
Description Precharge error with the internal DC Bus during initialization.
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action Disconnect the battery for 1 minute, and reboot the machine.
Troubleshooting Steps
3-083 Throttle Failband
3-084 Throttle Failband 2
Description The throttle input is outside of the permitted range.
Setting
Conditions
When Monitored
Always
Possible Causes Direct short in the throttle signal, or a short to a power source.
Initial Action
Troubleshooting Steps
3-113 Controller Over-Temp
Description
The internal drive controller sensor is reporting a temperature above operating limits.
The drive controller will be disabled.
Setting
Conditions
When Monitored
Always
Possible Causes
Initial Action Reboot the machine. If the error persists, replace the drive controller.
Troubleshooting Steps