Control System 30Service Manual – SC3000
Display of Current Values of Signicant Variables, Hour Counters and
Stored Alarms (continued)
Variable description Value meaning
Software Release Software version loaded on the electronic board
Supply Voltage Battery voltage (V)
Ref. Voltage Drive pedal input voltage (V)
Drive Motor Voltage Drive system motor output voltage (V)
Drive Motor Current Drive system motor current (A)
Brushes Current Brush deck motor current (mV) (*)
Vacuum Current Vacuum system motor current (A)
Heatsink Temp. Temperature detected on the electronic board heatsink (°C)
Hour counter: total TOTAL HOUR COUNTER (h.min)
Hour counter: drive system DRIVE SYSTEM HOUR COUNTER (h.min)
Hour counter: brushes BRUSH HOUR COUNTER (h.min)
Hour counter: vacuum VACUUM SYSTEM HOUR COUNTER (h.min)
Logged Alarm-N ALARM STORAGE (possible) (**)
(*) The value is the same as the voltage drop on the F1 fuse, which is proportional to the current but does not
have the same value in Amp.
(**) See BLACK-BOX paragraph