36Service Manual – SC401, SCRUBTEC 344 04 - Control System - Battery
Machine Settings (continues)
Parameter Description
Range
Resolution
Default
Permissions:
- = not visible
R = read only
W = read & write
Developer
Service/Tech
Production
NPI
Sales
Customer
Softstart Brush (ms) 0-25000 1 800 W R R R - -
Softstop Brush (ms) 0-2500 1 600 W R R R - -
Softstart Vacuum (ms) 0-25000 1 800 W R R R - -
Softstop Vacuum (ms) 0-2500 1 600 W R R R - -
Stopdelay Brush (ms) 0-25000 1 3000 W W R R - -
Stopdelay Vacuum (ms) 0-25000 1 5000 W W R R - -
Brush Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Brush Reduced Voltage (mV) 16500-42000 1 20000 W W R R - -
Brush Voltage Transition time (ms) 0-25000 1 3000 W W R R - -
Reduced Brush Consumption (mA) 0-25500 1 9000 W W R R - -
Vacuum Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Vacuum Reduced Voltage (mV) 16500-42000 1 16500 W W R R - -
Vacuum Voltage Transition time (ms) 0-25000 1 3000 W W R R - -
Solu. Pump Target Voltage (mV) 16500-42000 1 28000 W W R R - -
Det. Pump Target Voltage (mV) 16500-42000 1 28000 W W R R - -
T1on Pump state1 on time (ms) 5-255 1 7 W W R R - -
T1off Pump state1 off time (ms) 0-255 1 33 W W R R - -
T2on Pump state2 on time (ms) 5-255 1 17 W W R R - -
T2off Pump state2 off time (ms) 0-255 1 23 W W R R - -
T3on Pump state3 on time (ms) 5-255 1 40 W W R R - -
T3off Pump state3 off time (ms) 0-255 1 0 W W R R - -
Tm Pump time multiplier 1-255 1 100 W W R R - -
K Solution/Detergent flow ratio (x10) 0-1020 1 268 W W R R - -
%1 Detergent Level 1 percentage (x10) 0-50 1 2 W W R R - -
%2 Detergent Level 2 percentage (x10) 0-50 1 4 W W R R - -
%3 Detergent Level 3 percentage (x10) 0-50 1 8 W W R R - -
%4 Detergent Level 4 percentage (x10) 0-50 1 10 W W R R - -
%5 Detergent Level 5 percentage (x10) 0-50 1 20 W W R R - -
%6 Detergent Level 6 percentage (x10) 0-50 1 30 W W R R - -
--- CALIBRATION PARAMETERS --- W R - - - -
Current sum cutoff (mA) 0-51000 1 50000 W R R R - -
Brush peak current limit (mA) 0-51000 1 40000 W R R R - -
Vacuum peak current limit (mA) 0-51000 1 30000 W R R R - -
Brush continuous current limit (mA) 0-51000 1 25000 W W R R - -
Vacuum continuous current limit (mA) 0-51000 1 16000 W W R R - -
Time for continuous current overload (sec) 0-50 1 30 W W R R - -
Max softstart time multiplier 0-255 1 4 W R R R - -
Wait time softstart current limit (ms) 0-255 1 150 W R R R - -
Current limit during softstart (mA) 0-51000 1 50000 W R R R - -