8. Error messages / troubleshooting
8.1 Error messages
Display
Error Description
Troubleshooting
Fehler
Schütz Pumpe ausgelöst
1Q5 prüfen
The motor protection switch of the pump has
triggered. Check motor protection switch. If
this alarm occurs frequently, the pump must
be checked.
Turn the motor protection
switch back to position 1.
Fehler
Übertemperatur 16S13
prüfen
The temperature of the permeate
to 38 °C. The system switches off to protect
the membranes.
The system must be cooled
(see next page).
Fehler
Überdruck
16S4 prüfen
The permeate pressure has exceeded 6 bar.
Check the start and end of the
ring taps. Check setting of
permeate pressure retention
valve.
Fehler
Wassermangel
16S5 prüfen
The pressure switch 1 has responded.
Check water inlet.
Fehler
Leitfähigkeit
The conductivity has exceeded the limit of
100µS/cm.
There is probably a defect in
the membranes.
8.2 Clear alarms
Reset the error message
Follow the notes in Display.
Reset the alarm by pressing the F3 key