RM-994/ RM-995/ RM-996   
General Information   
  NOKIA INTERNAL USE ONLY  Page 27 
Copyright ©  2013 Nokia. All rights reserved. 
The HW module is not protected against water. Condensed or splashed water might cause malfunction. 
Any submersion of the phone will cause permanent damage. Long-term high humidity, with condensation, 
will cause permanent damage because of corrosion. 
 
Vibration 
The module should withstand the following vibrations: 
•  1200rpm 
•  50dB(A)max 
 
ESD strength 
Conducted discharge is 4 kV (>10 discharges) and air contact 8 kV (>10 discharges). 
The standard for electrostatic discharge is IEC 61000-4-2, and this device fulfills level 4 requirements. 
 
RoHS 
This device uses RoHS compliant components and lead-free soldering process.