SK 54xE – Users Manual for Frequency Inverters
50 BU 0505 EN-3021
2.8.3 Line filter SK HLD
With a chassis-mounted mains filter, radio interference class B (Class C1) can be
achieved up to a maximum motor cable length of 25 m.
When connecting the line filter, the "Wiring guidelines" Section (chapter 2.9.1) and
"EMC" Section (chapter 8.3) must be complied with. In particular, care must be taken
that the pulse frequency is set to the default value (P504 = 6kHz). The line filter
should be placed as close to the side of the inverter as possible.
The connection is by means of screw connections on the upper (mains) and lower
(inverter) ends of the filter
Inverter ID
Filter type
[-V/A]
L1 W1 D
Detail: Fastening Connection
cross-
section
L2 B2
SK 5xxE
250
323
A …
SK HLD 110-500/8
190 45 75 180 20 4
SK 5xxE
151
323
A …
SK HLD 110-500/16
250 45 75 240 20 4
SK 5xxE
301
323
A …
SK 5xxE
-551-323-A
SK HLD 110-500/30
270 55 95 255 30 10
SK 5xxE
152
323
A…
SK HLD 110-500/100
270 95 150 255 65 50
SK 5xxE
550
340
A…
SK HLD 110-500/8
190 45 75 180 20 4
SK 5xxE
301
340
A …
SK HLD 110-500/16
250 45 75 240 20 4
270 55 95 255 30 10
310 55 95 295 30 10
SK 5xxE
152
340
A…
SK HLD 110-500/55
250 85 95 235 60 16
SK 5xxE
372
340
A…
SK HLD 110-500/130
270 95 150 255 65 50
380 130 181 365 102 95
SK 5xxE
752
340
A…
SK HLD 110-500/250
450 155 220 435 125 150
SK 5xxE
113
340
A…
In preparation
All dimensions in mm mm
2
Table 19: Mains filter HLD-...
If the frequency inverter is used in a UL-relevant area, the mains filter can be selected according to the FLA value
which is assigned to the frequency inverter.
Example: SK 5xxE-302-340-A Input current rms: 84 A / FLA: 64.A
HLD 110-500/75
Pos: 63 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Elektr ischer Anschluss/E lektrischer Anschlu ss (Überschrif t+) [SK 1xxE, SK 2xxE, SK 5xxE, SK xxxE-FDS] @ 1\ mod_1342520847409_388. docx @ 33155 @ 2 @ 1
L1
L2
L3
L3'
L2'
L1'
L2
L1
B2
T
Netz / LINE
Gerät / LOAD
B1