8 Additional information
BU 0505 EN-3021 203
Setpoint source and
setpoint selection
Signal processing
and ramp
Control and motor
model (determination
8.8 Definition of setpoint and actual value processing (frequencies)
The frequencies used in parameters (P502) and (P543) are processed in various ways according the
following table.
Function Name Meaning
Right/
Left
with
Slip
I II III
8 Setpoint frequency
setpoint source
X
1 Actual frequency
Setpoint frequency for motor
model
X
23
with slip
Actual frequency at motor
X X
19
master value
setpoint source
Master value
(free from enable correction)
X X
20
n R master value
Setpoint frequency for motor
model
Master value
(free from enable correction)
X X
24
actual frequency
with slip
motorMaster value
(free from enable correction)
X X X
21
Actual frequency
without slip master
value
master value slip
Master value
X
Table 43: Processing of setpoints and actual values in the frequency inverter