E Series Automated Dispensing System
37www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setting System Parameters (continued)
Pre-Dispense Wait Time
Pre-dispense Wait Time is a wait time that occurs prior to the start of each dispense command within a program.
# Key Press Step Teach Pendant Display
1
> >
Press SETUP.
MOVE UP / DOWN to PRE-DISPENSE
WAIT TIME.
Press ENTER.
[SETUP] 2/3
08 Pause Status
09 Auto Purge
10 Pre-cycle Initialize
11*Pre-dispense Wait Time
12 Default Dispense Port
13 Needle Detect Setup
14 Run Limit
2
x >
Enter the desired value.
Press F1 to save or exit.
Pre-dispense Wait Time
------------------------------
Current Time: 0.0 s
New Time: 0.0 s
[F1] OK
Default Dispense Port (Dispense Port Output)
For most systems, a cable from the dispenser is connected to the Dispenser port on the back of the robot. The
default dispense output port for this connection is 0. The dispense port can also be set to any of the optional I/O
ports (ports 1 to 8).
NOTE: If the system includes a PICO
®
dispense valve cable, outputs 1 or 2 can be used. For multiple dispensers,
use the Dispense Port command (under the Type menu) within the dispense program to set the port for the
dispenser. Refer to “15 Dispense Port” on page102 for more information on the Dispense Port command.
# Key Press Step Teach Pendant Display
1
> >
Press SETUP.
MOVE UP / DOWN to DEFAULT
DISPENSE PORT.
Press ENTER.
[SETUP] 2/3
08 Pause Status
09 Auto Purge
10 Pre-cycle Initialize
11 Pre-dispense Wait Time
12*Default Dispense Port
13 Needle Detect Setup
14 Run Limit
2
x >
Enter the desired value (0 to 8).
NOTE: Port 0 refers to the Dispenser
port connector on the rear panel of the
robot.
Press F1 to save or exit.
Default Dispense Port
------------------------------
Port: 0
Port 0 is system default
[F1] OK

Table of Contents