E Series Automated Dispensing System
64 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Creating Patterns (continued)
How to Make an Arc (continued)
# Key Press Step Teach Pendant Display
7
>
Press SHIFT > 3 to register the location
as a Line End point.
Make XYZ coordinate changes as
needed.
Line End 1/4
------------------------------
X: 130.93 mm
Y: 37.39 mm
Z: 45.54 mm
[F1] OK [F2] Next [F3] Current
8
>
Press F2 to move through the Line End
parameter screens.
Press F1 to save and exit.
Line End 4/4
------------------------------
Retract Distance: 0.00 mm
Retract Low: 20.0 mm/s
Retract High: 80.0 mm/s
[F1] OK [F2] Next
9
>
Press SHIFT > END to register the end
of the program.
10
Press START to run the program.