EasyManua.ls Logo

Nortek Vectrino - Harness (Internal Wiring); Using Long Cables (Vector); Vectrino Profiler

Nortek Vectrino
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Comprehensive Manual88
© 2018 Nortek AS
3.9.3 Vectrino Profiler
Wet-end termination
Try-end termination
Underwater
connector
Pin.
No
Wire
Color
Descript
ion
Pin
Connector
(PMCIL-12-MP)
1
White
Rx+
3
DB-9 connector, pin 1 and 5 are grounded.
2
Black
Rx-
8
3
White/
Grey
Tx-
2
4
White/
Purple
Tx+
7
5
Not used
6
White/
Blue
Sync-
Terminal block
7
White/
Green
Sync+
8
Not used
9
Not used
10
Not used
11
White/
Brown
Power
Ground
Jacket
2-pin Jack plug
12
Black/
Red
Power +
Center
Shield
Power
Ground
Connected internally to Power Ground
Ref: N2100-304: RS422 cable for Vectrino Profiler
3.9.4 Using Long Cables (Vector)
RS232 data communication at 9600 baud will normally work fine for cables up to 50 m long,
depending on the environment. If you want to run a longer cable, you can switch to RS422 by
installing a different wiring harness you can get from Nortek.
You can also try using RS232 with longer cables by reducing the baud rate. Keep in mind that
RS422 is a more reliable means of communication than RS232 – changing environmental conditions
could cause RS232 communications to fail over a long wire without apparent reason.
You should consider voltage drop across the cable, particularly if you use the two highest power
settings. Design your power supply and cable so that the voltage stays below 16 VDC and never falls
below 9 VDC.
3.9.5 Harness (Internal wiring)
Figure: Harness and harness
pins