40
Removing the battery
Unplug the battery from the machine using the red
connection handle (Fig.48).
The battery can then be lifted from the machine for
storage or charging (Fig.49).
Recharge the machine fully after its last use.
Do not leave the machine in a discharged state.
Under abnormal use; i.e. leaving the machine without charging for a period of time, we advise that you disconnect
the battery from the machine.
If the machine will be standing unused for a period of 30 days or more, then batteries must be fully charged.
Note:
Batteries should be recharged every three months. Charge fully the day before you start using the machine again.
The battery pack comes tted with a 40 amp safety fuse (Fig.50).
Replace the fuse using (208526) Numatic approved part (Fig.51).
Removing the battery pack fuse
Battery Care
48
49
50
51