EasyManua.ls Logo

OEM PIZZAFORM - Page 64

OEM PIZZAFORM
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.0
4
[2]
[1]
[1][2]
[3]
[4]
The high position of the lower plate is detected by the sensor [1] when it intercepts the bar [2]
integral with the lower plate.
The low position of the lower plate is detected by the micro-switch [3] which stops the electrical
motor when it is pressed by the bar [4] integral with the lower plate.
Measurement of the plates temperature
The measurement of the plates temperature is done by two thermocouples [1], one for each
plate. The thermostats [2], depending on the difference between measured temperature and set
temperature, turn on or off the resistors set on the plates.