沖データ企業秘密・OkiDataCONFIDENTIAL
45530603TX −120/130
Priority
Status Message Ready
LED
Atten
LED
Function Status level
Error code
Status code
Error 7202: Cyan
Error 7203: Black
Error 7204: White
Error 7205: Clear
7203
7204
7205
40387(W)
40388(L)
382.5
1
2
3
Incompatible Belt Unit
Please see HELP for details
Off Blink
The detected belt unit is not optimal.
Invalid Belt Detected
Error
6885
40423
382.6
1
2
3
Incompatible Belt Unit
Please see HELP for details
Off Blink
The detected belt unit is not optimal.
Incomaptible Belt Detected
Error
6886
40424
382.7
1
2
3
Incompatible Fuser Unit
Please see HELP for details
Off Blink
The detected fuser unit is not optimal.
Invalid Fuser Detected
Error
6985
40425
382.8
1
2
3
Incompatible Fuser Unit
Please see HELP for details
Off Blink
The detected fuser unit is not optimal.
Incomaptible Fuser Detected
Error
6986
40426
382.9
1
2
3
Incompatible Fuser Unit
Please see HELP for details
Off Blink
Detection of a 110V fuser unit installed in a 220V device or a 220V fuser unit installed in a
110V device.
Error
6987
40395
383 1
2
3
4
5
Wait a Moment
Rebooting <%CODE%>
It may take some time to complete this process.
Off On Rebooting of the controller unit.
%CODE% is a decimal value (one digit) and represents the reason to reboot.
= 0 … Reboot due to a reason other than the followings.
= 1 … Reboot due to PJLCommand.
= 2 … Reboot in accordance with a menu change.
= 3 … Reboot due to quit operator of PostScript Language.
= 4 … reboot by Network Utility (including Web).
Error -
384 1
2
3
4
5
Shutting down
Please wait. Printer will turn off automatically
It may take some time to complete this process.
Off Off It is shown that a printer is shutting down.
Shutdown processing is started with which press BACK button 4 seconds or more after the
completion of initialization processing of a printer.
Error -
385 1
2
3
Turn off power
Shutdown completed
Off Off It is shown that the printer completed shutdown processing. (The backlight of LCD puts out
the light)
* This status is displayed for a split second at the instant preceding automatic power
shutoff. It is so brief that the display can hardly be seen.
Error -
401 1
2
3
Power Off and Wait for a while
126:Condensing Error
Off Blink
A dew is formed.
* Fatal Error is not available in national language.
Fatal
126
40057
401 1
2
3
Power Off/On
nnn:Error
Off Blink
A fatal error occurred.
For more information, see attached 'Fatal Errors List'.
* Fatal Error is not available in national language.
* "Status Code" and "USTATUS Message" can be acquired by MIB.
Fatal
<nnn>
40057
401 1
2
3
Service Call
nnn:Error
Off Blink
A fatal error occurred.
For more information, see "Service Calls List."
* Fatal Error is not available in national language.
Fatal
<nnn>
40057