List of the Device Setting Menu Items
-97-
Configuring at the Operator Panel
6
Management
Item
Factory
Default
Description
Default Mode Copy Sets the default mode of the machine.
Opera-
tion
Clear
Operation Timeout 3 Sets time of automatic reset. Available
range: 1 to 10 minutes.
Clear After Job OFF Sets whether to reset after any job is
completed.
Sound
Control
Key Touch Tone Volume Middle Sets the volume of the key-touch tone.
FAX Buzzer Volume Middle Sets the volume for transmission complete
acknowledgment.
LocalInte
rface
*1
USB Menu Soft Reset Disable Sets whether to enable the soft reset
command.
Speed 480 Mbps Selects the maximum transfer speed of
USB interface.
USB PS-Protocol RAW Selects a USB PS-protocol.
Offline Receive Disable Sets whether to receive data in offline
state or in recoverable error state.
Serial Number Enable Sets whether to use a USB serial number.
System
Setup
Access Control Disable Sets access control.
User Authentication Method Local Display condition: [Access Control] is set
to [User] or [Password].
Unit of Measure millimeter Selects a displayed unit (millimeter / inch)
of measure.
Date Format dd/mm/yyyy
Allow All Reports To Print Disable Sets whether to allow printing reports with
personal information.
Near Life LED Enable Sets whether to light an LED when a near
life warning occurs.
Status in Near Life Enable Sets whether a message is displayed when
a near life warning occurs.
Address Information Lock Time Out 3 minutes Sets time until a lock is released by the
machine when address book, telephone
book, or profile is kept locked by the utili-
ties. Available range: 1 to 10 minutes.
USB Memory Interface Enable When [Disable] is set. the scan to USB
and the print from USB memory functions
cannot be used.
Panel Contrast 0 Sets the LCD panel contrast. Available
range:
±10 (1 increments).
Power
Save
Power Save Time 1 minute Sets time to enter the power save mode.
Sleep Time 30 minutes Sets time to enter the sleep mode.
Auto Power Off Time 4 hours Sets time interval to turn off the
machine's power automatically.
Silent Mode ON (MB451/
MB451w/
MB471/
MB471w/
MB491/
ES4191MFP)
OFF (MB441/
MB461/
ES4161MFP)
Sets whether to enable the silent mode.

Table of Contents