COMPOSITION/OPERATION
8.2.3 Laser emission area
9. Imageing cartridge section
9.1 Composition
8.2.3 Laser emission area
A. Main scan direction (CD)
• The print start position in the CD direction is determined by the CD print start signal (/
HSYNC) that is output from the MFP board (MFPB) and the width of the media.
• The laser emission area is determined by the media size. The area of 4 mm on both
edges of the media is, however, the void image area.
B. Sub scan direction (FD)
• The print start position in the FD direction is determined by the Image write start signal (/
TOD) that is output from the MFP board (MFPB) and the length of the media.
• The laser emission area is determined by the media size. The area of 4 mm on both the
leading and trailing edges of the media is, however, the void image area.
8.2.4 Image stabilization control item
• LD intensity control
4138to2595c0
Void width: 4 mm
Void width: 4 mm
Void width: 4 mm
Void width: 4 mm
8.2.4 Image stabilization control item
9. Imageing cartridge section
9.1 Composition
A034T2C506AA
A034T2C554AA
Transfer belt
Photo conductor
Charge corona
Driven roller2
Driven roller1
1st transfer roller