OMICRON 7
Safety instructions
1.3 Operating the measurement setup
Switch off the high voltage.
Always obey the five safety rules and obey the following safety instructions.
Always obey the internal safety instructions for working in areas with high voltage to avoid injury.
Before operating the MPD 800 acquisition unit and its accessories, ground the setup as described in
1.2.2 "Safety rules" on page 6.
Make sure to clear the high-voltage area.
Observe the dangerous areas.
Before switching on the high voltage, leave the high-voltage area.
Make sure that the ground terminal of the test object is in good condition, clean, and free of oxidation.
Do not connect any cable to the test object without a visible grounding of the test object.
Always position the MPD 800 acquisition unit, the external quadripole (CPL1/CPL2) and the
rechargeable battery pack (RBP1) inside of the high-voltage area.
Always operate and place the Multi-device Control Unit (MCU2) and the PC in the work area.
Install the GPS antenna and its cabling in accordance with all national and local electrical codes,
regulations, and practices.
Install the antenna and cabling where they will not be energized by falling high-voltage power lines
and cannot be damaged by over-voltage transients, particularly lightning. Additional protective
measures are required for such installations, as specified in national and local electrical codes.
Never use the external power supply when the MPD 800 acquisition unit is operated at high-voltage
potential.
Never remove or attach any cables from the MPD 800 acquisition unit and its accessories or the test
object during a test.
Before operating the MPD 800 system in permanent installations with the OMICRON standard power
supply, be aware that a flashover or breakdown might invisibly damage the OMICRON 24 W DC
supply. Read the corresponding "Application Note" which can be found in the knowledge library within
OMICRON Customer Portal.
Do not use inadequately rated supply cords.
Do not insert objects (for example, screwdrivers) into any input/output socket.
Do not operate the MPD 800 acquisition unit or its accessories under ambient conditions that exceed
the temperature and humidity limits listed in 3 "Technical specifications" on page 52.
Check your additional equipment (for example, PC) for environmental conditions before use.
Always use dry and clean fiber-optic cables which are provided by OMICRON electronics. In dusty
regions, use protective caps. Make sure that the cables have ground contact to avoid leakage
current.
Do not use metal coated/jacketed conductive fiber-optic cables. Store the fiber-optic cables in a dry
area.
Do not operate the MPD 800 acquisition unit and its accessories in the presence of explosives, gas
or vapors.
Do not open the MPD 800 acquisition unit or its accessories housing.
Do not repair, modify, extend, or adapt the MPD 800 acquisition unit or its accessories.
Use only the MPD 800 acquisition unit original accessories available from OMICRON.