SPECIFICATIONS
Item Three-phase 200V class Specifications
3G3MX2 inverters, 200 V models A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150
Applicable
motor size
kW
VT 0.2 0.4 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5
CT 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
HP
VT 1/4 1/2 1 1.5 3 4 7.5 10 15 20 25
CT 1/8 1/4 1/2 1 2 3 5 7.5 10 15 20
Rated
capacity (kVA)
200 V
VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240 V
VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated input voltage Three-phase: 200 V-15% to 240 V+10%, 50/60 Hz±5%
Rated output voltage Three-phase: 200 to 240 V (proportional to input voltage)
Rated output current (A)
VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Starting torque 200% at 0.5 Hz
Braking
Without resistor
100%: at 50 Hz
50%: at 60 Hz
70%: at
50 Hz
50%: at
60 Hz
100%: at 50 Hz
50%: at 60 Hz
100%: at
50 Hz
50%: at
60 Hz
With resistor 150%
DC braking Variable operating frequency, time, and braking force
We ig ht
kg 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.3 3.4 5.1 7.4
lb 2.2 2.2 2.4 2.6 3.5 4.0 4.4 7.3 7.5 11.2 16.3
Item Three-phase 400V class Specifications
3G3MX2 inverters, 400 V models A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 A4110 A4150
Applicable
motor size
kW
VT 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
CT 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
HP
VT 1 2 3 4 57.510152025
CT 1/2 1 2 3 4 5 7.5 10 15 20
Rated capacity
(kVA)
380 V
VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
480 V
VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated input voltage Three-phase: 380 V-15% to 480 V+10%, 50/60 Hz±5%
Rated output voltage Three-phase: 380 to 480 V (proportional to input voltage)
Rated output current (A)
VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Starting torque 200% at 0.5 Hz
Braking
Without resistor
100% at 50 Hz
50%: at 60 Hz
70%: at
50 Hz
50%: at
60 Hz
100%: at 50 Hz
50%: at 60 Hz
With resistor 150%
DC braking Variable operating frequency, time, and braking force
We ig ht
kg 1.5 1.6 1.8 1.9 1.9 2.1 3.5 3.5 4.7 5.2
lb 3.3 3.5 4.0 4.2 4.2 4.6 7.7 7.7 10.4 11.5