96
Instruction Support and Operand Restrictions Section 2-6
2-6-26 Clock Instructions
Instruction Mnemonic Function
code
Symbol Operands Supported
variable
data types
AT
setting or
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
CALENDAR ADD CADD
@CADD
730 C: 1st calendar
word
WORD Yes (3)
T: 1st time word DWORD Yes (2)
WORD
must be
used
when
array vari-
ables are
required.
R: 1st result word WORD Yes (3)
CALENDAR SUB-
TRACT
CSUB
@CSUB
731 C: 1st calendar
word
WORD Yes (3)
T: 1st time word DWORD Yes (2)
WORD
must be
used
when
array vari-
ables are
required.
R: 1st result word WORD Yes (3)
HOURS TO SEC-
ONDS
SEC
@SEC
065 S: 1st source word DWORD Yes (2)
WORD
must be
used
when
array vari-
ables are
required.
D: 1st destination
word
DWORD Yes (2)
WORD
must be
used
when
array vari-
ables are
required.
CADD
C
T
R
CSUB
C
T
R
SEC
S
D