77
Instruction Support and Operand Restrictions Section 2-6
FLOATING TO 32-
BIT
FIXL
@FIXL
451 S: 1st source word REAL ---
R: Result word DINT ---
16-BIT TO FLOAT-
ING
FLT
@FLT
452 S: Source word INT ---
R: 1st result word REAL ---
32-BIT TO FLOAT-
ING
FLTL
@FLTL
453 S: 1st source word DINT ---
R: Result word REAL ---
FLOATING-POINT
ADD
+F
@+F
454 Au: 1st augend
word
REAL ---
Ad: 1st addend
word
REAL ---
R: 1st result word REAL ---
FLOATING-POINT
SUBTRACT
-F
@-F
455 Mi: 1st Minuend
word
REAL ---
Su: 1st Subtrahend
word
REAL ---
R: 1st result word REAL ---
FLOATING- POINT
MULTIPLY
*F
@*F
456 Md: 1st Multiplicand
word
REAL ---
Mr: 1st Multiplier
word
REAL ---
R: 1st result word REAL ---
FLOATING- POINT
DIVIDE
/F
@/F
457 Dd: 1st Dividend
word
REAL ---
Dr: 1st Divisor word REAL ---
R: 1st result word REAL ---
DEGREES TO RADI-
ANS
RAD
@RAD
458 S: 1st source word REAL ---
R: 1st result word REAL ---
RADIANS TO
DEGREES
DEG
@DEG
459 S: 1st source word REAL ---
R: 1st result word REAL ---
Instruction Mnemonic Function
code
Symbol Operands Supported
variable
data types
AT
setting or
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
FIXL
S
R
FLT
S
R
FLTL
S
R
+F
Au
Ad
R
-F
Mi
Su
R
* F
Md
Mr
R
/F
Dd
Dr
R
RAD
S
R
DEG
S
R

Table of Contents