136
Appendix
Parameter Flow
• If you press the mode key at the last parameter in each level, you return to the top parameter in that level.
Set the alarm output
3 ON/OFF states.
Alarm 3 open in alarm
Alarm 3 hysteresis
Advanced function setting
level
key 1 second min.
Parameter initialization
Number of multi-SP uses
Select 2 or 4 SPs.
Set multi-SP and
run/stop input.
Event input assignment 1
Event input assignment 2
Multi-SP uses
SP ramp set value
Change rate during SP
ramp
Standby sequence reset
Reset conditions after
standby sequence is canceled.
Set the alarm output
1 ON/OFF states.
Alarm 1 open in alarm
Alarm 1 hysteresis
Set the alarm output
2 ON/OFF states.
Alarm 2 open in alarm
Alarm 2 hysteresis
HB ON/OFF
Heater burnout latch
Latch after HBA
detection
Heater burnout
hysteresis
ST stable range
Set the deviation.
Advanced PID parameter
Alpha
MV upper limit
MV lower limit
Input digital filter
Set the time constant in
seconds.
Additional PV display
Displayed first in the
operation level.
MV display
Automatic display return time
Automatic return to operation level
when the keys on the front panel are
operated.
Alarm 1 latch
Alarm 2 latch
Alarm ON latch
Alarm 3 latch
Move to protect level time
Input error output
Cold junction compensa-
tion method
MB command logic
switching
Alarm 1 ON delay
Alarm 2 ON delay
Alarm 3 ON delay
Alarm 1 OFF delay
Alarm 2 OFF delay
Alarm 3 OFF delay
Password input set
value "−169"
key 1 second min.
key 3 seconds min.
Initial setting level
Input type
Scaling upper limit
0 to 50 mV
Scaling lower limit
Decimal point
°C/°F selection
Limit the set point.
SP upper limit
SP lower limit
PID ON/OFF
Select the control method.
Standard or heating/cooling
ST
Self-tuning
Control period (OUT1)
Set the pulse output
cycle.
Control period (OUT2)
Direct/reverse operation
Control the manipulated variable
according to the increase/decrease
in the PV.
Alarm 1 type
Select the alarm mode.
Alarm 2 type
Alarm 3 type
Move to advanced function
setting level.
Restriction is MV
calculated value
Select the alarm mode.
Select the alarm mode.
init
off
eV-m
1
eV-1
none
eV-2
stop
mspu
off
sprt
off
C
rest
a
al1n
n-o
C
alh1
0.2
C
al2n
n-o
C
ol-h
105.0
in-t
5
in-h
100
in-l
0
dp
0
d-u
c
sl-h
1300
C
sl-l
-200
C
cntl
onof
s-hc
stnd
st
on
cp
20
c-cp
20
oreV
or-r
alt1
2
alt2
2
alt3
2
amoV
0
ol-l
-5.0
inf
0.0
pVad
off
o-dp
off
ret
off
a1lt
off
a2lt
off
a3lt
off
prlt
3
sero
off
cjc
on
rlrV
off
a1on
0
a2on
0
a3on
0
a1of
0
a2of
0
a3of
0
alh2
0.2
C
al3n
n-o
C
alh3
0.2
C
hbu
on
hbl
off
hbh
0.1
st-b
15.0
C
alfa
0.65