Calculations and Judgements Using Inspection Item Data
FQ2-S4 User’s Manual
4
Setting Up Inspections
207
2D-code Judgement JG −2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
−2
Index No. IN −2: Verification OFF or reading error,
−1: Verification is NG,
0 to 31: Master data No.
−2
Num. of char. N 0 to 1024 0
2D-code (DPM) Judgement JG −2: No judgement (not measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not performed error,
−14: Figure not registered error,
−15: Out of range error
−2
Index No. IN −2: Verification OFF or reading error,
−1: Verification is NG,
0 to 31: Master data No.
−2
Num. of char. N 0 to 1024 0
Cell Recog. Rate E 0 to 100 0
Contrast C 0 to 100 0
Focus F 0 to 100 0
Search Judgement JG −2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
−2
Correlation CR[0] to CR[31] 0 to 100 0
Position X X[0] to X[31] −99999.9999 to 99999.9999 0
Position Y Y[0] to Y[31] −99999.9999 to 99999.9999 0
Angle TH[0] to TH[31] −180 to 180 0
Reference X SX −99999.9999 to 99999.9999 0
Reference Y SY −99999.9999 to 99999.9999 0
Reference angle ST −180 to 180 0
Detection X RX −99999.9999 to 99999.9999 0
Detection Y RY −99999.9999 to 99999.9999 0
Count C 0 to 32 0
Shape Search II Judgement JG −2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
−2
Correlation CR 0 to 100 0
Position X X −99999.9999 to 99999.9999 0
Position Y Y −99999.9999 to 99999.9999 0
Angle TH −180 to 180 0
Reference X SX −99999.9999 to 99999.9999 0
Reference Y SY −99999.9999 to 99999.9999 0
Reference angle ST −180 to 180 0
Detection X RX −99999.9999 to 99999.9999 0
Detection Y RY −99999.9999 to 99999.9999 0
Count C 0 to 32 0
Inspection item Data name Expression text
string
Data range Default