Appendix D Operation Timing Chart
Relationship between Start Input and Output (bank not used)
Bank Switching Timing
ON
Start input
Output status
(Cam output, RUN output)
T1
T2
OFF
T1: max. 225ms
T2: max. 225ms
Output prohibited Output prohibited
Output enabled
Start
input
Bank 0
Bank 0 Bank 1 Bank 2
Bank 1
Bank 2
T2
T4
T1 T2 T3
Operation
ON
OFF
ON
OFF
RUN
output
Unstable region (outputs OFF) T1: 225 ms max.
T2: 400 ms max.
T3: 20 ms min.
T4: 20 ms min.
Bank
specification