5-13
OPERATION
Appropriate setting of the
"move-to-protect-level time"
parameter allows you to
change the time required for
the product to move to the
protect level.
The move-to-protect-level
time is factory set to 5
seconds.
5-9 Key Protect Setting
Procedure
A. When the product is at the operation level, press
the L+M keys and hold them down for at least
five seconds to enter the protect level.
•"
p
" will appear on the level indicator, indicating
the product has entered the protect level.
B. Press the M key several times until the desired
parameter appears on the main indicator
C. Press the S key to display the set value of the
parameter on the main indicator.
• The current set value will appear on the main
indicator
D. Press the S key again.
• The current set value will start blinking, indicat-
ing the product is in the change state.
E. Use the U key to change the set value.
F. Press the M key to go to the next parameter.
• The change is saved.
G. Press the L+M keys and hold down them for at
least one second to return to the operation level.