3-7 Changing Address Status/Contents
3-7-3 Changing Present Values of Specified Words
74
3-7-3 Changing Present Values of Specified Words
Note
• Carefully check that the system is safe before using the Ladder Monitor to perform
any of the following actions, or before using a CX-Programmer or Programming
Console to perform any of these actions from another node while the Ladder Monitor
is running.
- Changing monitoring data
- Changing the operating mode
- Force setting/resetting bits
- Changing set values or present values
If unspecified persons may start the Ladder Monitor, use a password to prevent
incorrect operation. Refer to 3-14 Using a Password for details on the password
function.
Use the following procedure to change the present value of a word that is being
monitored.
1. In the ladder display area or from the Multiple I/O Monitor, press the address for
which the value is to be changed. The address will be selected (with the cursor
displayed there).
2. Press the Change Button.
(2)
Change
Button
1
Selected
(1) Selected
3. The Change Value Dialog Box will be displayed.