219
Programming Console Function Section 6-12
When the sending of data to the printer is completed, Finished Normal by
Printer Interface Check is displayed.
If data does not reach the printer within 60 seconds after sending starts,
the message ‘Finished Printer output failed’ is displayed.
After confirming the result of the check, press Quit. The NT31/NT31C returns
to the I/F CHECK MENU screen.
6-12 Programming Console Function
The NT31/NT31C has been equipped with the Programming Console func-
tion, which allows it to be used like a C200H-PRO27-E Programming Console
for CPM1, CPM2A, CPM2C, CQM1, CQM1H, C200HX/HG/HE (-Z)E, CS/CJ-
series, or SRM1 PLCs.
Except for recording (saving) ladder programs on cassette tape and replaying
(reading) them, almost all the functions of a Programming Console can be
executed.
Note When the programmable controller functions are used, carefully check that
the system is safe before carrying out the following operations.
Changing monitor data
Switching the operating mode
Forced set or reset
Changing a present value or set value