EasyManua.ls Logo

Omron NT31

Omron NT31
707 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
505
Changing Numeral and Character String Display
Section 8-5
S Program operation
(1) The value “1” is added to the contents of D0000 every second. At the
NT31/NT31C, the displayed value of the numeral memory table No. 1 in-
creases by “1” every second.
(2) Each time carry over occurs during processing at (1) above, the contents of
D0001 are incremented by 1. At the NT31/NT31C, the value of the higher 4
digits in numeral memory table No.1 increases by 1.
(3) When bit 00001 comes ON, the value 1” is added to the contents of D0002.
At the NT31/NT31C, the displayed value of numeral memory table No. 2
increases by “1”.
[Indirect specification]
The following shows an example of changing the displayed numeric value by
adding a value to the contents of a numeral memory table allocated word which
is referenced in indirect specification.
S Setting at the Support Tool
Set as indicated below using the Support Tool.
- Numeral memory table No. 51:
D0000 (Value: 100, Words: 1, Storage Type: BCD)
- Numeral memory table No. 100:
D0010 (Words: 1, Storage Type: BCD)
- Numeral memory table No. 101:
D0011 (Words: 1, Storage Type: BCD)
- Touch switch (upper):
@ Function setting: Notify Bit
@ PC Address: 0000100
@ Action Type: “Momentary”
@ Label: TARGET
- Touch switch (lower):
@ Function setting: Notify Bit
@ PC Address: 0000101
@ Action Type: “Momentary”
@ Label: ACHIEVED
- Contents to be registered for the screen:
Numeral display (numeral memory table No. 51, indirect specification),
touch switches (two, indicated above)

Table of Contents