590
Commands/Responses
Section 9-3
Response
[Format]
None
[Function]
S In accordance with operations at the PT, such as numeral setting and copying of
memory tables, notifies the host that a numeric value has been input to the nu-
meral memory table.
S Since it is not possible to write to numeral memory tables from No.247 to No253
(areas for clock data display/reading use only), notification of these tables is not
executed.
Example
S Command
t1
1B 53
[ESC] S
d4
t4
4E
Nt2t3
0D
d1 d2
d3
d8d5 d6 d7 s1 s2 [CR]
** **** ** ** **
** **** ** ** **
** **
Input numeral memory table number : No.150
Input numeric value data (hexadecimal) : 30000H
Check sum (hexadecimal) : 05H
Here, it is ascertained that 30000 has been input to numeral memory table No.150
(whether this is 30000 in hexadecimal or 30000 in BCD is determined by the nu-
meral storage type set for the numeral memory table).
00196608
00030000
00030000
00030000
Input numeral Numeral memory table No. 150