618
Examples of Actual Applications of Memory Link
Section 10-2
S Explanation
- Check sum present/absent : None (writing 1 word)
- First numeral memory table No. written : 142
- Data of written numeral memory table : 000004B0
H
(1200 in decimal)
In this way, numeral data which is input from the PT is processed at the host and
the result is notified to the PT.
Hints
S Same as numeral, character string input notify command (sent from PT to
host) is issued from the PT for the character string which is input at PT. (see
page )
S Character string which is input from bar code reader is also notified to the host.
(see page )
S Data of numeral/character string memory table can be cleared by memory table
clear command. (Numerals are cleared to 0”, and character strings are cleared
to the space code 20 H) (see page )