EasyManuals Logo

Omron NT31 User Manual

Omron NT31
707 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #629 background imageLoading...
Page #629 background image
618
Examples of Actual Applications of Memory Link
Section 10-2
S Explanation
- Check sum present/absent : None (writing 1 word)
- First numeral memory table No. written : 142
- Data of written numeral memory table : 000004B0
H
(1200 in decimal)
In this way, numeral data which is input from the PT is processed at the host and
the result is notified to the PT.
Hints
S Same as numeral, character string input notify command (sent from PT to
host) is issued from the PT for the character string which is input at PT. (see
page )
S Character string which is input from bar code reader is also notified to the host.
(see page )
S Data of numeral/character string memory table can be cleared by memory table
clear command. (Numerals are cleared to 0”, and character strings are cleared
to the space code 20 H) (see page )

Table of Contents

Other manuals for Omron NT31

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NT31 and is the answer not in the manual?

Omron NT31 Specifications

General IconGeneral
BrandOmron
ModelNT31
CategoryTouch terminals
LanguageEnglish

Related product manuals