617
Examples of Actual Applications of Memory Link
Section 10-2
(1) When numeral data is input on PT (“numeral input notify command” sent from
PT to host):
S Command
0
1B 53
[ESC] S
34
30
0
32
2
4E
N1
3130
4
0
30
0
0
31
1
0
30 46
F0
30
39
9
3030
0D
[CR]
(3)
(2)
(1)
0
30
S Explanation
- Numeral memory table number : 142
- Input numeral : 00000000F0
H
(240 in decimal)
- Check sum : 19H
It is ascertained that “240” is input to numeral memory table No.142. With numeral
input notify command, input numeral data is expressed as binary. Here, input data
(240) is expressed as binary (000000F0
H
).
(2) When numeral is written to PT (“numeral memory table write command” (sent
from host to PT) )
S Command
8
1B 57
[ESC] W
31
30
0
34
4
4E
N0
3038
1
0
30
0
04
34 42
B0
303030 0D
[CR]
(3)
(1)
0
30
32
2
(2)