9-16
9-3 Vibration Suppression Settings
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
9
Details on Servo Parameter Objects
 Set the notch frequency of resonance suppression notch filter 2.
 The notch filter function is disabled if this object is set to 5000.
 Refer to 11-7 Notch Filters on page 11-21.
 Select the notch width of resonance suppression notch filter 2.
 Increasing the setting value widens the notch width. Normally, use the default set value.
 Refer to 11-7 Notch Filters on page 11-21.
 Set the notch depth of resonance suppression notch filter 2.
 Increasing the setting value shortens the notch depth and the phase lag.
 Refer to 11-7 Notch Filters on page 11-21.
 Set the notch frequency of resonance suppression notch filter 3.
 The notch filter function is disabled if this object is set to 5000.
 While the adaptive filter is enabled, the resonance frequency 1 that is assumed by the adaptive
filter is automatically set. If no resonance point is found, the value 5000 is set.
 Refer to 11-6 Adaptive Filter on page 11-18 and 11-7 Notch Filters on page 11-21.
 Select the notch width of resonance suppression notch filter 3.
 Increasing the setting value widens the notch width. Normally, use the default set value.
 While the adaptive filter is enabled, this object is set automatically.
 Refer to 11-6 Adaptive Filter on page 11-18 and 11-7 Notch Filters on page 11-21.
3204 hex
Notch 2 Frequency Setting
Setting
range
50 to 5000 Unit Hz
Default
setting
5000
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
All
3205 hex
Notch 2 Width Setting
Setting
range
0 to 20 Unit −
Default
setting
2
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3206 hex
Notch 2 Depth Setting
Setting
range
0 to 99 Unit −
Default
setting
0
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3207 hex
Notch 3 Frequency Setting
Setting
range
50 to 5000 Unit Hz
Default
setting
5000
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3208 hex
Notch 3 Width Setting
Setting
range
0 to 20 Unit −
Default
setting
2
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3209 hex
Notch 3 Depth Setting
Setting
range
0 to 99 Unit −
Default
setting
0
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
All
All
All
All
All

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 Series and is the answer not in the manual?

Omron OMNUC G5 Series Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 Series
CategoryServo Drives
LanguageEnglish

Related product manuals