9-15
9-3 Vibration Suppression Settings
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
9
Details on Servo Parameter Objects
9-3 Vibration Suppression Settings
 Set the operation of the adaptive filter.
 Refer to 11-6 Adaptive Filter on page 11-18.
Explanation of Set Values
 Set the frequency of resonance suppression notch filter 1.
 The notch filter function is disabled if this object is set to 5000.
 Refer to 11-7 Notch Filters on page 11-21.
 Set the width of resonance suppression notch filter 1 to one of 20 levels.
 Increasing the setting value widens the notch width. Normally, use the default set value.
 Refer to 11-7 Notch Filters on page 11-21.
 Set the notch depth of resonance suppression notch filter 1.
 Increasing the setting value shortens the notch depth and the phase lag.
 Refer to 11-7 Notch Filters on page 11-21.
3200 hex
Adaptive Filter Selection
Setting
range
0 to 4 Unit −
Default
setting
0
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
csp
Set
value
Description
0 Adaptive filter disabled
1 One adaptive filter is enabled. The objects related to notch filter 3 are automatically updated.
2 Two adaptive filters are enabled. The objects related to notch filters 3 and 4 are updated.
3 For use by manufacturer. Do not use this setting.
4
Adaptive result is cleared. Objects related to notch filters 3 and 4 are disabled and the
adaptive result is cleared.
3201 hex
Notch 1 Frequency Setting
Setting
range
50 to 5000 Unit Hz
Default
setting
5000
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
All
3202 hex
Notch 1 Width Setting
Setting
range
0 to 20 Unit −
Default
setting
2
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
All
3203 hex
Notch 1 Depth Setting
Setting
range
0 to 99 Unit −
Default
setting
0
Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible.
All

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 Series and is the answer not in the manual?

Omron OMNUC G5 Series Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 Series
CategoryServo Drives
LanguageEnglish

Related product manuals