RFID System
Operation Manual
Section 5 Communications Commands
Section 5
Communications
1:N Communications
Write Command information is cleared under the following conditions.
If the ID Controller's power supply is reset
A command input error will occur if WRITE REPEAT is executed under this condition.
Command code The command code of the most recently executed Write Command.
End code Indicates the results of command execution.
00: Normal end
Refer to End Codes for more information.
p.135
Command
Command code
RP
2
2
*CR
Terminator
2
xx
FCS
3
Controller No.
x
@
x
Response
Command code
xx
00
22
2
*CR
Terminator
End code
2
xx
FCS
3
Controller No.
x
@
x

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C