125
RFID System
Operation Manual
Section 5 Host Device Commands
Section 5
Communications
Host Device Commands
TEST (TS)
For TEST, the ID Controller returns the test message sent from the host device without any changes.
Use TEST to text communications between the host device and ID Controller.
1:1 Communications
1:N Communications
Test data Any text string for testing communications. Up to 262 characters can be specified.
Test data Any text string for testing communications. Up to 262 characters can be specified.
Command
Command code
TS
xx
x
2
2
*CR
Terminator
x
n
Test data
Response
Command code
TS
xx
x
2
2
*CR
Terminator
x
n
Test data
Command
Command code
TS
xx
x
2
2
*CR
Terminator
x
n
Test data
2
xx
FCS
3
Controller No.
x
@
x
Response
Command code
TS
xx
x
2
2
*CR
Terminator
x
n
Test data
2
xx
FCS
3
Controller No.
x
@
x

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C