124
Section 5 General Communications Subcommands
RFID System
Operation Manual
Section 5
Communications
ABORT (XZ)
If the ID Controller does not return a response due to a problem during host communications or during
communications with a Data Carrier, the ABORT command can be executed to restore the ID
Controller to the Command Wait Status.
No response will be returned to the ABORT command.
1:1 Communications
The ID Controller requires about 100 ms before it can receive the next command after it receives the ABORT command.
1:N Communications
The ID Controller requires about 100 ms before it can receive the next command after it receives the ABORT command.
Command
Command code
XZ
2
2
*CR
Terminator
Command
Command code
x
Z
2
2
*CR
Terminator
2
xx
FCS
3
Controller No.
x
@
x

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals